Calculator

Heating load calculator: How much heat does your room need?

Heat demand, connections or pipe length: choose a calculator and find the right solution for your bathroom.

  1. Heat demand Heat demandHow much heat your room needs – with the right radiators.
  2. Radiator Finder FinderFind the right model in three questions.
  3. Exchange Finder ExchangeWhich radiator fits your connections?
  4. Flow temperature Lead timeHow much a radiator contributes to your heating.
  5. Pipe supplies Pipe requirementsHow much pipe your underfloor heating needs.

1 · Heat demand

Calculate the heat requirement per room

Area, ceiling height, insulation and room – the result and suitable radiators appear immediately.

Building insulation
Room
How should the radiator be heated?
Connection
Include flow temperature (optional)

The shop output figures apply to 75/65/20 °C. If your heating runs cooler, for example with a heat pump, we recalculate each model for your temperatures.

Gauge: heat requirement per square metre, scale 0 to 150 W/m² 0 150 W/m²

Enter the surface area, insulation, and room.

Estimate – does not replace a heat load calculation according to DIN EN 12831.

How it is calculated

Heat requirement = area × insulation value × room factor × ceiling height ÷ 2.5 m. The guideline values come from the previous Helia Bad heat load calculator and are listed below.

Calculation method

How the heating load calculator works

An estimate based on four inputs. It does not account for windows, external walls or ventilation.

Example formula: bathroom, 12 m², well renovated, 2.5 m high
Area12 m² × Insulation value70 W/m² × Room factor1,1 × Ceiling height ÷ 2.5 m1,0 = Heat requirement924 W

Insulation value

  • 50W/m²Very good (new build)
  • 70W/m²Good (renovated)
  • 100W/m²Medium (standard)
  • 130W/m²Poor (old building)

Room factor

  • 1,0×Living room
  • 1,1×Bathroom
  • 0,9×Bedroom
  • 0,95×Kitchen
  1. Calculate heat requirement

    Area × insulation value × room factor × ceiling height ÷ 2.5 m.

  2. Compare output

    Suitable if the radiator delivers at least the required heat. With 10 % or more reserve: “good fit”.

  3. Flow temperature

    Cooler heating, lower output: we convert according to EN 442.

  4. Electric

    For electric radiators, the heating element output applies.

Detailed calculation and guideline tables
Heat requirement (W)
Area (m²) × insulation value (W/m²) × room factor × ceiling height (m) ÷ 2.5
Good fit / close fit
Output at least requirement × 1.1 / between requirement and requirement × 1.1
Different flow temperature (EN 442)
Output = rated output × (ΔT ÷ 49.83 K)n, ΔT = (flow − return) ÷ ln((flow − room) ÷ (return − room)); n from the datasheet, otherwise 1.3. Example: 1,000 W at 75/65/20 °C gives about 511 W at 55/45/20 °C.
Guideline values from the previous Helia Bad heat load calculator
InsulationInsulation value
Very good (new build)50 W/m²
Good (renovated)70 W/m²
Medium (standard)100 W/m²
Poor (old building)130 W/m²
Room factors from the previous Helia Bad heat load calculator
RoomFactor
Living room1,0
Bathroom1,1
Bedroom0,9
Kitchen0,95

Estimate – does not replace a heat load calculation according to DIN EN 12831. Ask your installer for precise sizing.

2 · Radiator Finder

Finding the right radiator in three questions

Question 1 of 3

How is the radiator supposed to heat?
Replace an old radiatoropen the replacement finder (centre distance)

View calculation method or take flow temperature into account? To the heating load calculator above

3 · Exchange Finder

Which radiator fits your existing connections?

A replacement radiator fits without modification if the hub spacing and connection type are correct. Measure the distance between the two connection pipes and enter it.

How to measure the connection centres Radiator with two connection pipes, either vertically at the side or at the bottom, depending on the connection type. The centre distance is measured from the centre of one pipe to the centre of the other. Centre distance Centre distance
Measure from the center of one connection pipe to the center of the other – in millimeters.
Where do the pipes connect?
Which side is the connection on? (optional)

4 · Flow temperature

What heat output suits your heating system?

The output shown in the shop is for 75/65/20 °C according to EN 442. If your heating system runs cooler, for example with a heat pump, the same radiator will output less heat. Enter the output from the product page.

Flow / return
Gauge: proportion of the output at 75/65/20 °C 0 % 100 %

Specify the power at 75/65/20 °C.

How it is calculated

Output = output at 75/65/20 °C × (ΔT ÷ 49.83 K)n, using the logarithmic excess temperature ΔT = (flow − return) ÷ ln((flow − room) ÷ (return − room)) according to EN 442. We use the exponent n from the datasheet; if none is specified, we use the standard value 1.3.

Heat visualization for flow, return and room temperatures Heat visualization of a radiator at a flow temperature of 55 °C, a return temperature of 45 °C and a room temperature of 20 °C. The closer the heating water temperature is to room temperature, the weaker the heat glow. °C 20 40 60 80 Room 20 °C Return 45 °C Flow 55 °C

5 · Piping requirements

Underfloor heating: How much pipe do you need?

Enter the heated area and the pipe spacing. You will get the pipe length, the number of heating circuits, and how many rolls you need.

Pipe spacing
Gauge: length of each heating circuit compared with the maximum length 0 m 100 m

Enter the heated area.

View product: Underfloor heating pipe PE-RT 16x2 mm

How it is calculated

Pipe length = area ÷ pipe spacing + 10 % for connection pipes (rule of thumb). A heating circuit should be no longer than about 100 m; this is a guideline for 16 × 2 mm pipe. The specifications of your manifold and pipe system take precedence. A heating circuit must not be spliced across two rolls. The actual circuit layout depends on the rooms and should be planned by your installer.