Lowering the flow temperature: The radiator test in winter

A simple test on cold days will show whether your home can cope with lower heating temperatures. Here’s how to carry it out and interpret the results.

by Helia Bad Redaktion6 min read

Ventilheizkörper KONRAD Typ 22 in Weiß an einer hellen Wohnzimmerwand, daneben ein Leinensessel

In short: If you want to lower the flow temperature, the best way to test it is on cold winter days: bleed the radiators, open the thermostatic valves, and lower the heating curve step by step, waiting one day between each step. The room that is the first to no longer get warm will reveal the radiator that is holding you back. This will show you what temperature your home can really cope with.

In February, winter is often still properly cold. For many, this is the most uncomfortable time of the year, but it is ideal for a heating test. Only on cold days can you see whether the radiators can still bring enough heat into the rooms with cooler water.

The test costs nothing except a little attention over one to two weeks. It is interesting for anyone who wants to save energy, and especially for anyone considering a heat pump.

What the flow test shows

The flow temperature is the temperature of the water flowing from the heating system to the radiators. Many systems are set higher than they need to be because that always works. Every degree lower makes condensing boilers and heat pumps operate more efficiently.

How far you can lower it is determined by the weakest room. If a radiator is undersized for its room, it needs hotter water, and the entire system has to accommodate it. The test identifies exactly this room.

Prepare the test properly

For the results to be meaningful, the system should be in good condition:

  • Bleed all radiators. Air in the radiator will distort the results. Where it comes from is explained in the post Air in the heating system.
  • Check the system pressure on the pressure gauge. If it is too low, leave the refilling to the heating specialist.
  • Set the thermostatic valves in the rooms in use to the setting that corresponds to the desired temperature, or open them fully.
  • Place a simple thermometer in each room, not directly at the radiator.
  • Find out where the heating curve and flow temperature are displayed and adjusted on your heating system. This is stated in the manual.

Tip: Note the initial setting of the heating curve before you change anything. This way you can always return to it if it gets too cold.

How the test works step by step

  1. Wait until a cold spell with frost is forecast.
  2. Lower the heating curve by one small step, as described in your heating system's manual.
  3. Wait one day so that all rooms can settle.
  4. In the evening, note down the values: outdoor temperature, flow temperature, and the temperature in each room.
  5. If all rooms remain warm enough, lower it by the next step.
  6. If a room no longer gets warm, reverse the last step and make a note of the room.
Day Outdoor Flow Coldest room
1 note note Room and temperature
2 note one step lower Room and temperature
3 note one step lower Room and temperature

Unsure about the setting? Then do the test together with your heating specialist, for example at the next service. They can also set the heating curve and hydraulic balancing correctly at the same time.

How to interpret the results correctly

In the end, you will know two things: the lowest flow temperature at which all rooms remained warm on a cold day, and the room that was the first to struggle. The lower this temperature, the better the conditions for economical heating and for a heat pump.

How much the output of a radiator drops with a falling temperature is shown by the KONRAD Type 22 radiator in 600 × 1000 mm:

Heating water (flow/return/room) Output
75/65/20 °C 1,754 W
70/55/20 °C 1,411 W
55/45/20 °C 884 W

At 55/45/20 °C, it therefore delivers about half the output it does at 75/65/20 °C. The flow calculator calculates this for your own radiators: You enter the output at 75/65/20 °C and see what is left at your temperatures.

The effect is particularly noticeable in the bathroom because it is supposed to be warmer there. The HALDEN bathroom radiator in white delivers 1,054 watts at 75/65/20 °C, and still 495 watts at 55/45/20 °C. If the bathroom is the coldest room in the test, it is worth taking a look at these figures.

What you can do with the result

If the test has revealed a bottleneck, there are several options. Often, it is enough to replace one or two radiators with larger ones. Then the entire system can run at a lower temperature. Which radiators should be replaced first is explained in the post Heat pump in existing buildings.

Sometimes the bottleneck is not the radiator, but the distribution: The room does not get enough water because no hydraulic balancing has been carried out. The heating specialist checks and adjusts this. And if all rooms remained warm even at a low setting, simply keep it that way.

Frequently asked questions

Does it get cold in the apartment during the test?

A room may briefly get a little cooler if you reach the limit. That is exactly the result you are looking for. Then reverse the last step, and the next day it will be back to normal.

Why should the test take place on cold days?

In mild weather, the rooms need little heat, and almost every radiator can manage that even with cool water. Only in frost does it become clear which room reaches its limit.

Does the test affect the hot water in the bathroom?

In most systems, it does not, because the drinking water is heated via a separate setting. Check the manual of your heating system to see whether the heating curve and hot water are set separately.

What do I do if only the bathroom does not get warm enough?

This is common because the bathroom is supposed to be warmer than the other rooms. Then a larger bathroom radiator or an electric supplement in the bathroom will help. You can still operate the rest of the house at the lower setting if the bathroom is supplied separately.

Check what your radiators can deliver at a low temperature

Enter the output of your radiator at 75/65/20 °C and see how much heat is left at your flow temperature.

Open flow calculator View all radiators

More on this topic:Heat pump

Radiator Finder

Find the right radiator in three questions

Question 1 of 3

How should the radiator be heated?
Replace an old radiatoropen the replacement finder (centre distance)

View calculation or consider flow temperature? Calculate the heating load for your room

How much heat does your room need?

With the heating load calculator, you estimate the heat requirements of your room and find suitable models.

Calculate the heating load for your room

More from the shop

Browse all models, sizes and colours.

View All radiators